Tandem Diabetes Care Announces NEJM Publication of Study Demonstrating Increased Time in Range in Young Children with Type 1 Diabetes Using the t:slim X2 Insulin Pump with Control-IQ Technology
Tandem Diabetes Care, Inc. (NASDAQ: TNDM) announced favorable results from the Pediatric Artificial Pancreas (PEDAP) Clinical Trial, published in the New England Journal of Medicine. Children aged 2-5 using the t:slim X2 insulin pump with Control-IQ technology experienced an approximate 3-hour daily increase in time in range compared to standard insulin treatments. Key findings showed a 12.4% adjusted mean difference in time in range and a 0.5% decrease in Hemoglobin A1c levels. The trial included 101 participants, with 94% system usability, indicating significant improvements in glucose control.
- Mean time in range with Control-IQ technology increased from 57% to 69%, a 12.4% adjusted difference.
- Hemoglobin A1c decreased by 0.5% from baseline, with a median improvement of 0.42%.
- 94% median active closed loop time, with all but one trial participant completing the study.
- No increase in hypoglycemia recorded in young children using Control-IQ technology.
- None.
Results observed in this randomized, controlled trial for subjects using Control-IQ technology, an automated insulin delivery (AID) system, were immediate, sustained, and observed across the spectrum of patient characteristics including race-ethnicity, parental education, family income, baseline glycated hemoglobin level, virtual vs. in-person training format, and pre-study insulin delivery method. Subjects with higher baseline hemoglobin A1c values (A1c) experienced greater improvements in time in range and A1c during the study.
“The safety and efficacy outcomes observed in this study support using Control-IQ technology for young children with type 1 diabetes to enhance quality of life and minimize the risk of long-term complications,” said Dr.
“After the resounding success of Control-IQ technology in people ages six and up, it is very rewarding to see our youngest patients, and often the most challenging patients to help, benefit as well,” said Dr.
“Use of the t:slim X2 insulin pump with Control-IQ technology demonstrated substantial improvements in glucose control, particularly overnight, with no increase in hypoglycemia in young children,” said
Key Data Highlights
Glycemic Control Over 13 Weeks
- Mean time in range with Control-IQ technology increased from 57 percent at baseline to 69 percent during follow-up compared to 55 percent to 56 percent in the control group, for a mean adjusted difference of 12.4 percent.
- Hemoglobin A1c decreased 0.5 percent from baseline with Control-IQ technology, a median improvement of 0.42 percent compared to the control group.
- Time spent in hyperglycemia (>250 mg per deciliter) was 5.4 percentage points less with Control-IQ technology than the control group.
- Time spent in hypoglycemia (<70 mg per deciliter) was low but not significantly different between groups.
- Results with Control-IQ technology were immediate (evident within 1 day of initiation) and sustained.
- Nighttime mean time in range was 74 percent with Control-IQ technology versus 56 percent in the control group and daytime was 67 percent versus 56 percent, respectively.
- Total daily insulin dose and weight change appeared similar between the Control-IQ technology and standard care groups.
System Performance and Useability
- The median time the system was in active closed loop was 94 percent.
- Results were observed regardless of pre-study experience with an insulin pump.
- The 13-week trial was completed by all but one patient (101 of 102 enrolled.)
This was a 13-week randomized, multi-center trial, featuring 101 children age 2 to <6 years old with type 1 diabetes. Patients previously using a hybrid closed-loop system were excluded. Participants were assigned two to one to Closed Loop Control (N=68) or Standard Care (N=34) which included either an insulin pump or multiple daily injections of insulin plus a CGM. Baseline glycated A1c levels ranged from 5.2 percent to 11.5 percent. Clinical training was virtual for 81 percent of the participants using Control-IQ technology and follow-up visits were 91 percent virtual.
This study was funded by the
These data will be published in the
Study Reference:
Wadwa RP, Reed ZW, Buckingham BA, et al. Trial of Hybrid Closed-Loop Control in Young Children with Type 1 Diabetes. N Engl J Med. 2023;388:991-1001. DOI: 10.1056/NEJMoa2210834
Results from the Protocol 3 study (DCLP3) of the
* Time in range is defined as 70-180 mg/dL and is measured by CGM.
** The algorithm used in this study was identical to the commercial version of Control-IQ technology, except for the ability to enter a lower body weight and total daily insulin value at system initialization.
About
Follow
Follow
Follow
Forward-looking Statements
This press release contains “forward-looking statements” within the meaning of Section 27A of the Securities Act of 1933, as amended, and Section 21E of the Securities Exchange Act of 1934, as amended. These forward-looking statements relate to, among other things, our goal to establish that Control-IQ technology could be a powerful management solution for therapy needs of children age 2 to <6 years old with type 1 diabetes. These forward-looking statements are subject to numerous risks and uncertainties, including risks associated with the research and development process generally, such as the design, testing and validation of products and related systems in compliance with applicable regulatory and legal requirements in the markets that we serve, the real-world clinical benefits from use of Control-IQ technology may not match the results reported in the study and the level of customer satisfaction from the use of our products and features may be different from what we expect, our ability to develop, scale and maintain systems, personnel and infrastructure to support customers across diverse geographies and market segments, as well as other risks identified in our most recent Annual Report on Form 10-K and Quarterly Reports on Form 10-Q, and other documents that we file with the
Responsible use of Control-IQ technology
Control-IQ technology does not prevent all highs and lows. Users must still bolus for meals and actively manage their diabetes. Visit tandemdiabetes.com/safetyinfo for additional important safety information.
Important Safety Information: RX ONLY. The t:slim X2 pump and Control-IQ technology are intended for single patient use. The t:slim X2 pump and Control-IQ technology are indicated for use with U-100 insulin only. t:slim X2 insulin pump: The t:slim X2 insulin pump with interoperable technology is an alternate controller enabled (ACE) pump that is intended for the subcutaneous delivery of insulin, at set and variable rates, for the management of diabetes mellitus in people requiring insulin. The pump is able to reliably and securely communicate with compatible, digitally connected devices, including automated insulin dosing software, to receive, execute, and confirm commands from these devices. The t:slim X2 pump is indicated for use in individuals six years of age and greater. Control-IQ technology: Control-IQ technology is intended for use with a compatible integrated continuous glucose monitor (iCGM, sold separately) and ACE pump to automatically increase, decrease, and suspend delivery of basal insulin based on iCGM readings and predicted glucose values. It can also deliver correction boluses when the glucose value is predicted to exceed a predefined threshold. Control-IQ technology is intended for the management of Type 1 diabetes mellitus in persons six years of age and greater.
WARNING: Control-IQ technology should not be used by anyone under the age of six years old. It should also not be used in patients who require less than 10 units of insulin per day or who weigh less than 55 pounds.
Control-IQ technology is not indicated for use in pregnant women, people on dialysis, or critically ill patients. Do not use Control-IQ technology if using hydroxyurea. Users of the t:slim X2 pump and Control-IQ technology must: use the insulin pump, CGM, and all other system components in accordance with their respective instructions for use; test blood glucose levels as recommended by their healthcare provider; demonstrate adequate carb-counting skills; maintain sufficient diabetes self-care skills; see healthcare provider(s) regularly; and have adequate vision and/or hearing to recognize all functions of the pump, including alerts, alarms, and reminders. The t:slim X2 pump, and the CGM transmitter and sensor must be removed before MRI, CT, or diathermy treatment. Visit tandemdiabetes.com/safetyinfo for additional important safety information.
© 2023
View source version on businesswire.com: https://www.businesswire.com/news/home/20230315005716/en/
Media Contact:
858-255-6388
media@tandemdiabetes.com
Investor Contact:
858-366-6900
IR@tandemdiabetes.com
Source:
FAQ
What were the results of the Tandem Diabetes PEDAP Clinical Trial published in 2023?
What is the significance of the Control-IQ technology for young children with diabetes?
How many participants were involved in the Tandem Diabetes PEDAP Clinical Trial?
What is the stock symbol for Tandem Diabetes Care?