New Study Evaluates the Use of Masimo PVi® As an Indicator of Fluid Responsiveness to Guide Goal-Directed Fluid Therapy in Adult Neurosurgical Patients
Masimo (NASDAQ: MASI) announced findings from a study published in the British Journal of Neurosurgery indicating that the noninvasive Pleth Variability Index (PVi) is as effective as the invasive stroke volume variation (SVV) for guiding intraoperative fluid management during neurosurgery. Conducted among 60 adult patients undergoing elective craniotomy, the study suggests PVi may be preferable given its noninvasive nature. Although fluid volume administered was higher in the SVV group (3208.3 mL vs. 2139.3 mL), other clinical outcomes like serum lactate and stay duration showed comparable results. CEO Joe Kiani emphasized PVi's cost-effectiveness and low risk.
- PVi shown to be equally effective as SVV for fluid therapy in neurosurgery.
- Noninvasive nature of PVi may reduce complications associated with invasive procedures.
- Study supports the use of PVi in managing fluid levels without arterial catheters.
- Higher volume of fluid administered in SVV group may suggest limitations of PVi in certain contexts.
Researchers Found That Noninvasive, Continuous PVi Was Equally Effective in Guiding Fluid Management As Stroke Volume Variation (SVV), an Invasive Method Requiring an Arterial Line
Masimo Root® with PVi® (Photo: Business Wire)
Noting the value of GDFT for neurosurgical patients in particular, but that most of the dynamic parameters traditionally used to guide GDFT, such as SVV, are invasive, requiring the use of an intra-arterial catheter (an arterial line, or “A-line”), which is associated with a variety of complications, the researchers sought to determine whether a noninvasive parameter, PVi, whose measurements are derived from the photoplethysmographic waveform, might serve as a reliable predictor of fluid responsiveness in such a population. PVi, or pleth variability index, is a measure of the variations in perfusion index over the respiratory cycle, and is indicated as a noninvasive, dynamic indicator of fluid responsiveness in select populations of mechanically ventilated adult patients.
To test their hypothesis, the researchers randomly divided 60 adult patients undergoing elective craniotomy into two groups: one whose intraoperative fluid administration was guided by PVi (n=29) and the other, by SVV (n=31). In the PVi group, patients were monitored using Masimo Radical-7® Pulse CO-Oximeters® with noninvasive pulse oximetry fingertip sensors. In the SVV group, SVV was invasively measured using an Edwards Lifesciences Vigileo/FloTrac device connected to a cannulated radial artery. The researchers compared the total amount of intravenous fluid administered during surgery, as well as serum lactate and serum creatinine levels at pre-determined time points, the brain relaxation score at dural opening and closure, and correlation between PVi and SVV values. They also compared duration of mechanical ventilation and length of hospital stay.
As noted in the table below, the researchers found that the volume of fluid administered intraoperatively was significantly higher in the SVV group. The other parameters and outcomes they measured were comparable between the two groups: serum lactate, serum creatinine, brain relaxation score, duration of mechanical ventilation, and length of hospital stay, as noted below. The researchers also observed “a moderate to strong correlation between SVV and PVi at corresponding points of time during the intraoperative period. This suggests that PVi, derived noninvasively from the pulse oximetry waveform, is a reliable indicator of fluid responsiveness.”
Outcome |
PVi group |
SVV group |
p-Value |
Volume of fluid administered |
2139.3 ± 898.6 mL (mean) |
3208.3 ± 1836.2 mL (mean) |
0.005 |
Serum lactate level, over time |
Ranging from 1.59 ± 0.91 to 2.73 ± 1.18 |
Ranging from 1.79 ± 0.97 to 2.44 ± 0.88 |
Ranging from 0.55 to 0.82 |
Serum creatinine level, over time |
Ranging from 0.64 ± 0.14 to 0.66 ± 0.15 mg/dL |
Ranging from 0.64 ± 0.17 to 0.71 ± 0.21 mg/dL |
Ranging from 0.23 to 0.86 |
Brain relaxation score |
2 (1-3) at dural opening, 2 (12) at dural closing (median) |
2 (1-4) at dural opening and closing (median) |
0.49 (opening) 0.33 (closing) |
Duration of mechanical ventilation |
19.09 ± 15.9 hours (mean)
|
27.9 ± 15.9 hours (mean) |
0.1 |
Length of hospital stay |
12.6 ± 19.26 days (mean) |
16.4 ± 26.8 days (mean) |
0.53 |
The researchers concluded, “Based on the findings of our study, we conclude that PVi and SVV are equally effective for guiding intraoperative goal directed fluid therapy in adult neurosurgical patients scheduled for elective craniotomy for supratentorial brain tumors. However, PVi, being a noninvasive parameter, may be preferable.” They continued, “The two groups in our study were comparable with respect to serum creatinine and serum lactate measured at predetermined time points intraoperatively and post operatively. The two groups were also comparable with respect to brain relaxation scores at dural opening and dural closure. There was moderate to strong correlation between SVV and PVi at corresponding time points intraoperatively. The duration of mechanical ventilation and the length of hospital stay was also comparable between the two groups.”
In the US, PVi is FDA 510(k) cleared as a noninvasive dynamic indicator of fluid responsiveness in select populations of mechanically ventilated adult patients. Accuracy of PVi in predicting fluid responsiveness is variable and influenced by numerous patient, procedure and device related factors. PVi measures the variation in the plethysmography amplitude but does not provide measurements of stroke volume or cardiac output. Fluid management decisions should be based on a complete assessment of the patient’s condition and should not be based solely on PVi.
@Masimo | #Masimo
About Masimo
Masimo (NASDAQ: MASI) is a global medical technology company that develops and produces a wide array of industry-leading monitoring technologies, including innovative measurements, sensors, patient monitors, and automation and connectivity solutions. In addition, Masimo Consumer Audio is home to eight legendary audio brands, including Bowers & Wilkins, Denon, Marantz, and Polk Audio. Our mission is to improve life, improve patient outcomes, and reduce the cost of care. Masimo SET® Measure-through Motion and Low Perfusion™ pulse oximetry, introduced in 1995, has been shown in over 100 independent and objective studies to outperform other pulse oximetry technologies.3 Masimo SET® has also been shown to help clinicians reduce severe retinopathy of prematurity in neonates,4 improve CCHD screening in newborns,5 and, when used for continuous monitoring with Masimo Patient SafetyNet™ in post-surgical wards, reduce rapid response team activations, ICU transfers, and costs.6-9 Masimo SET® is estimated to be used on more than 200 million patients in leading hospitals and other healthcare settings around the world,10 and is the primary pulse oximetry at 9 of the top 10 hospitals as ranked in the 2022-23
ORi, RPVi, and Radius VSM have not received FDA 510(k) clearance and are not available for sale in
References
-
Dey A, Bidkar PU, Swaminathan S, Kumari M, Joy JJ, Balasubramanian M, Bhimsaria S. Comparison of two techniques of goal-directed fluid therapy in elective neurosurgical patients – a randomized controlled study. Br
J Neuosurgery .3 Feb 2023 . DOI: 10.1080/02688697.2023.2173722/ - Published clinical studies on PVi can be found on our website at http://www.masimo.com.
- Published clinical studies on pulse oximetry and the benefits of Masimo SET® can be found on our website at http://www.masimo.com. Comparative studies include independent and objective studies which are comprised of abstracts presented at scientific meetings and peer-reviewed journal articles.
- Castillo A et al. Prevention of Retinopathy of Prematurity in Preterm Infants through Changes in Clinical Practice and SpO2 Technology. Acta Paediatr. 2011 Feb;100(2):188-92.
- de-Wahl Granelli A et al. Impact of pulse oximetry screening on the detection of duct dependent congenital heart disease: a Swedish prospective screening study in 39,821 newborns. BMJ. 2009;Jan 8;338.
- Taenzer A et al. Impact of pulse oximetry surveillance on rescue events and intensive care unit transfers: a before-and-after concurrence study. Anesthesiology. 2010:112(2):282-287.
- Taenzer A et al. Postoperative Monitoring – The Dartmouth Experience. Anesthesia Patient Safety Foundation Newsletter. Spring-Summer 2012.
-
McGrath S et al. Surveillance Monitoring Management for General Care Units: Strategy, Design, and Implementation.
The Joint Commission Journal on Quality and Patient Safety . 2016 Jul;42(7):293-302. - McGrath S et al. Inpatient Respiratory Arrest Associated With Sedative and Analgesic Medications: Impact of Continuous Monitoring on Patient Mortality and Severe Morbidity. J Patient Saf. 2020 14 Mar. DOI: 10.1097/PTS.0000000000000696.
- Estimate: Masimo data on file.
- http://health.usnews.com/health-care/best-hospitals/articles/best-hospitals-honor-roll-and-overview.
Forward-Looking Statements
This press release includes forward-looking statements as defined in Section 27A of the Securities Act of 1933 and Section 21E of the Securities Exchange Act of 1934, in connection with the Private Securities Litigation Reform Act of 1995. These forward-looking statements include, among others, statements regarding the potential effectiveness of Masimo PVI®, SpHb®, and Radical-7®. These forward-looking statements are based on current expectations about future events affecting us and are subject to risks and uncertainties, all of which are difficult to predict and many of which are beyond our control and could cause our actual results to differ materially and adversely from those expressed in our forward-looking statements as a result of various risk factors, including, but not limited to: risks related to our assumptions regarding the repeatability of clinical results; risks related to our belief that Masimo's unique noninvasive measurement technologies, including Masimo PVi, SpHb, and Radical-7, contribute to positive clinical outcomes and patient safety; risks that the researchers’ conclusions and findings may be inaccurate; risks related to our belief that Masimo noninvasive medical breakthroughs provide cost-effective solutions and unique advantages; risks related to COVID-19; as well as other factors discussed in the "Risk Factors" section of our most recent reports filed with the
View source version on businesswire.com: https://www.businesswire.com/news/home/20230306005560/en/
Masimo
949-396-3376
elamb@masimo.com
Source: Masimo
FAQ
What are the findings of the study on PVi by Masimo?
How does PVi compare to SVV according to the study?
What was the sample size of the Masimo PVi study?
What was the primary measurement compared in the Masimo study?