Waters Peptide Multi-Attribute Method for BioAccord System Boosts Innovator and Biosimilar Drug Development and Commercialization
Waters Corporation (NYSE: WAT) has unveiled a new peptide multi-attribute method (MAM) workflow for its BioAccord™ LC-MS System. This innovation allows scientists in drug development and QC to efficiently monitor the efficacy and safety of monoclonal antibodies and protein-based drugs. The workflow enhances the analysis of critical quality attributes (CQAs), including product variants and impurities, improving decision-making in manufacturing. This system aims to democratize mass spectrometry use by making it accessible to scientists with limited experience.
- Introduction of peptide MAM workflow improves analytical capabilities for protein-based drugs.
- Enables efficient monitoring of critical quality attributes (CQAs) improving decision-making in manufacturing.
- Democratizes access to mass spectrometry, allowing more scientists to utilize advanced analytics.
- None.
Waters Corporation (NYSE:WAT) today introduced a new peptide multi-attribute method (MAM) workflow for the Waters™ BioAccord™ LC-MS System, enabling drug development, manufacturing, and QC scientists to monitor efficacy and safety through the analysis of critical quality attributes (CQAs) of monoclonal antibodies (mAbs) and other protein-based drugs.
New Peptide MAM (multi-attribute method) workflow for the BioAccord LC-MS System monitors product quality attributes that can affect efficacy and safety of innovator drugs and biosimilars. (Photo: Business Wire)
“The BioAccord System moves attribute-based monitoring out of centralized MS labs and into the hands of more scientists in regulated and quality control laboratories who may not have extensive experience operating mass spectrometers,” said Jeff Mazzeo, Ph.D., Vice President – Global Marketing and Scientific Operations, Waters Corporation. “With this new method for the BioAccord System on the waters_connect platform, scientists have a single, sensitive multiplexed method to accurately assess the most important attributes of protein-based drugs that enable rapid decision-making for product development, manufacturing, and release.”
The peptide MAM workflow for the BioAccord System monitors for:
- Product variants
- Product degradation and impurities
- Process stability-indicating modifications
Quality Assistance, a leading contract research organization based in Belgium, uses the Waters BioAccord System as part of a comprehensive portfolio of mass spectrometry services it provides to the pharmaceutical industry.
“Investing in state-of-the-art equipment is essential for remaining at the forefront of analytical sciences,” says Dr. Arnaud Delobel, R&D Director, Quality Assistance. “Our Waters BioAccord System strengthens our ability to meet the needs of customers for robust and reproducible results with full traceability and data integrity from injection to reporting. Automated workflows for intact mass, peptide mapping and monitoring as well as for released N-glycans analysis provide us with reliable results quickly.”
The BioAccord System pairs the ACQUITY™ UPLC™ I-Class Plus with the ACQUITY RDa™ Mass Detector featuring SmartMS™ enabled usability features. The system offers a wide range of users with varying MS experience, industry-leading automated setup and self-diagnosis capability delivered through modern instrument control software and an intuitive user interface, all within a small footprint. In addition to peptide MAM, the BioAccord System also features workflows for other routine analyses of biotherapeutics: peptide mapping, intact/subunit mass analysis, released glycan profiling and oligonucleotide mass confirmation.
waters_connect™: A Single, Platform for LC and LC-MS Applications
waters_connect is a compliant-ready informatics platform enabling scientists to manage functionality of BioAccord System in workstation or laboratory networked deployments. It’s a growing platform of streamlined purpose-built applications that enhances the value that the BioAccord System brings to everyday sample analysis. Providing a complete audit trail for acquisition, processing and reporting of data, waters_connect meets and exceeds expectations for regulatory compliance, while maintaining the highest standards of data integrity.
Additional Resources
- Download the applications note: A Streamlined Compliant-Ready Workflow for Peptide-Based Multi-Attribute Method (MAM)
- Visit our web site: BioAccord LC-MS System for Biopharmaceuticals
- Watch the video: Multi-Attribute Method Overview
- Learn about waters_connect: waters_connect: All Your Applications in One Interface
- Read our blog post: Biopharma’s Future: Next-Generation LC-MS Workflows for Peptide MAM
- Connect with Waters via LinkedIn, Twitter, and Facebook
About Waters Corporation (www.waters.com)
Waters Corporation (NYSE:WAT), the world's leading specialty measurement company, has pioneered chromatography, mass spectrometry, and thermal analysis innovations serving the life, materials, food and environmental sciences for more than 60 years. With more than 7,400 employees worldwide, Waters operates directly in 35 countries, including 14 manufacturing facilities, and with products available in more than 100 countries.
Waters, ACQUITY, UPLC, ACQUITY UPLC, SmartMS, RDa, BioAccord and waters_connect are trademarks of Waters Corporation.
View source version on businesswire.com: https://www.businesswire.com/news/home/20210318005518/en/
FAQ
What is the new innovation by Waters Corporation on the BioAccord System?
How does the peptide MAM workflow benefit scientists?
What are the critical quality attributes monitored by the new workflow?
When was the new peptide MAM workflow announced?