Pacira Announces Publication of Phase 4 Study of EXPAREL in Cesarean Section Procedures in Anesthesia & Analgesia
Pacira BioSciences announced the publication of its Phase 4 study results for EXPAREL in Anesthesia and Analgesia. The study showed a 52% reduction in total opioid consumption at 72 hours post-C-section when combined with bupivacaine, and a statistically significant increase in opioid-spared patients (54% vs 25%). The study spanned 13 sites and involved 136 patients. Safety was comparable between groups, with 64% of the EXPAREL group experiencing treatment-emergent adverse events. This data could enhance postoperative pain management strategies, especially given that C-sections pose significant opioid use concerns.
- 52% reduction in opioid consumption through 72 hours.
- 54% of patients in the EXPAREL group were opioid-spared, a significant increase.
- Safety profile was comparable between EXPAREL and bupivacaine HCl groups.
- 41% reduction in opioid consumption at two weeks did not reach statistical significance.
- 64% of patients in the EXPAREL group experienced treatment-emergent adverse events.
– Results show an opioid-reducing benefit of adding EXPAREL to bupivacaine transversus abdominis plane (TAP) blocks for cesarean delivery –
PARSIPPANY, N.J., Aug. 05, 2020 (GLOBE NEWSWIRE) -- Pacira BioSciences, Inc. (NASDAQ: PCRX) today announced that full results its Phase 4 study of EXPAREL® (bupivacaine liposome injectable suspension) administered via transversus abdominis plane (TAP) field block in patients undergoing Cesarean section (C-section) have been published in Anesthesia and Analgesia. In this study, EXPAREL achieved its primary endpoint with a statistically significant reduction in total postsurgical opioid consumption through 72 hours. EXPAREL also achieved statistical significance for reduction in percentage of opioid-spared patients through 72 hours.
This was a multicenter, randomized, double-blind study across 13 clinical sites in the United States, in patients undergoing elective C-section and receiving spinal anesthesia and a multimodal analgesic regimen. Patients were randomized (1:1) to receive EXPAREL 266 mg plus bupivacaine HCl 50 mg or bupivacaine HCl 50 mg alone administered via TAP field block after delivery. Effectiveness was evaluated in a pre-specified modified intent-to-treat (mITT) population which met the study criteria regarding proper administration of TAP and multimodal regimen (N=136). Key findings include:
- Significant reduction in total opioid consumption with EXPAREL plus bupivacaine HCl versus bupivacaine HCl
52% reduction through 72 hours, the primary endpoint of the study (least squares mean [LSM] standard error [SE], 15.5 [6.67] vs 32.0 [6.25] mg, respectively; P=0.0117)49% reduction at one week (LSM [SE], 23.3 [9.75] vs 45.8 [9.13] mg, respectively; P=0.0175)
41% reduction of opioid consumption at two weeks, although results did not reach statistical significance (LSM [SE], 28.2 [11.20] vs 47.8 [10.49] mg, respectively; P=0.0542)- Significantly higher percentage of opioid-spared patients with EXPAREL versus bupivacaine HCl, defined as patients who took no more than one oxycodone 10 mg tablet (or equivalent) with no opioid-related side effects through 72 hours
- Percentage of opioid-spared patients was 2.2 times higher in the EXPAREL group vs bupivacaine HCl group (
54% vs25% , respectively; P=0.0012)
- Percentage of opioid-spared patients was 2.2 times higher in the EXPAREL group vs bupivacaine HCl group (
- Optimized pain control through 72 hours, which was comparable in both groups
Patients in the EXPAREL arm of this study were administered a TAP field block with 10 mL EXPAREL admixed with 10 mL
Research shows nearly nine in 10 mothers and mothers-to-be have concerns about taking opioids during and after childbirth, yet
“With C-sections being one of the most common surgeries in the United States, and data showing that one out of 300 opioid naïve women become persistent opioid users following cesarean delivery, it’s critical we evaluate our approach to postsurgical pain management,” said Ashraf Habib, MD, Chief, Division of Women’s Anesthesia and Professor of Anesthesiology at Duke University and study investigator. “The data from this Phase 4 study demonstrate that an EXPAREL-based multimodal regimen has the potential to optimize postoperative analgesia for C-section patients.”
Prior to C-section, all patients in this study received an intrathecal injection of 150 mcg preservative-free morphine for spinal injection in conjunction with single-shot spinal anesthesia using 1.4-1.6 mL bupivacaine HCl
Safety was comparable between study groups, with 64 percent of patients in the EXPAREL group experiencing a treatment-emergent adverse event (TEAE) versus 56 percent of patients in the bupivacaine HCl group. The most common TEAEs include pruritus (itching) and nausea; serious TEAEs were rare (approximately three percent in both groups). There were no fatal TEAEs.
Earlier this year, Pacira announced positive topline results for CHOICE, a next-generation C-section trial designed to eliminate the use of spinal morphine in the EXPAREL arm. In the study, EXPAREL achieved its primary endpoint with a statistically significant reduction in total opioid consumption while maintaining pain scores through 72 hours (P≤0.001), and demonstrated statistical significance for the key secondary endpoint of a reduction in the incidence and severity of itching for 72 hours after surgery (P≤0.05).
About Pacira BioSciences
Pacira BioSciences, Inc. (NASDAQ: PCRX) is a leading provider of non-opioid pain management and regenerative health solutions dedicated to advancing and improving outcomes for health care practitioners and their patients. The company’s long-acting local analgesic, EXPAREL® (bupivacaine liposome injectable suspension) was commercially launched in the United States in April 2012. EXPAREL utilizes DepoFoam®, a unique and proprietary product delivery technology that encapsulates drugs without altering their molecular structure, and releases them over a desired period of time. In April 2019, the company acquired the iovera⁰ system, a handheld cryoanalgesia device used to deliver precise, controlled doses of cold temperature only to targeted nerves. To learn more about Pacira, including the corporate mission to reduce overreliance on opioids, visit www.pacira.com.
About EXPAREL
EXPAREL (bupivacaine liposome injectable suspension) is indicated for single-dose infiltration in adults to produce postsurgical local analgesia and as an interscalene brachial plexus nerve block to produce postsurgical regional analgesia. Safety and efficacy have not been established in other nerve blocks. The product combines bupivacaine with DepoFoam®, a proven product delivery technology that delivers medication over a desired time period. EXPAREL represents the first and only multivesicular liposome local anesthetic that can be utilized in the peri- or postsurgical setting. By utilizing the DepoFoam platform, a single dose of EXPAREL delivers bupivacaine over time, providing significant reductions in cumulative pain scores with up to a 78 percent decrease in opioid consumption; the clinical benefit of the opioid reduction was not demonstrated. Additional information is available at www.EXPAREL.com.
Important Safety Information
EXPAREL is contraindicated in obstetrical paracervical block anesthesia. Adverse reactions reported with an incidence greater than or equal to
Company Contact:
Pacira Pharmaceuticals, Inc.
Susan Mesco, (973) 451-4030
Susan.Mesco@pacira.com
Media Contact:
Coyne Public Relations
Alyssa Schneider, (973) 588-2270
aschneider@coynepr.com
FAQ
What were the results of the Phase 4 study for EXPAREL published recently?
How does EXPAREL improve pain management for C-section patients?
What was the sample size of the Phase 4 study involving EXPAREL?
What were the key findings regarding safety in the EXPAREL study?